- Characteristics:
- closed loop hall current sensor, hall magnetic compensation principle, can be isolated to measure AC, DC, pulse current
- Model: HAB55
- Rated input (effective value): 50A
- Measuring range: 0 +80A
- Rated output: 50mA
- Accuracy: ±0.5%
- Linearity: 0.15%
- Supply voltage (±5%): ±15V
- Current consumption: 10mA+Im
- Measured impedance: 10-100Ω
- Zero offset, TA=25°C: ±0.3mA
- Response time: <1μs
- Bandwidth: DC 150kHz
- Dielectric strength (50Hz 1 minute): 2.5kV
- Operating temperature: -25 to +85°C
- Storage temperature: -25 to +100°C
- Mounting type: PCB
- Fire resistance UL94-V0
- Standards: EN50178
- Weight: 16g
- Model: HAB55
- Rated input (effective value): 100A
- Measuring range: 0+150A
- Rated output: 50mA
- Accuracy: ±0.5%
- Linearity: 0.15%
- Supply voltage (±5%): ±15V
- Current consumption: 10mA+Im
- Measured impedance: 50Ω
- Zero offset, TA=25°C: ±0.2mA
- Response time: <1μs
- Bandwidth: DC 200kHz
- Dielectric strength (50Hz 1 minute): 2.5kV
- Operating temperature: -25 to +85°C
- Storage temperature: -25 to +100°C
- Mounting type: PCB
- Fire resistance UL94-V0
- Standards: EN50178
- Weight: 18g
|
|
|
|