1. Using conditions
Item
|
Unit
|
Min
|
Typ
|
Max
|
Test Conditions
|
Operating Temperature
|
℃
|
-20
|
|
60
|
|
Relative Humidity
|
%RH
|
40
|
|
90
|
No cooling
|
2
Technical requirements
2.1
Input Characteristics
Item
|
Unit
|
Min
|
Typ
|
Max
|
Test
Conditions
|
Input Voltage Range
|
V
ac
|
85
|
110/220
|
265
|
Under
full load condition
|
Input Voltage Range
|
V dc
|
100
|
150/300
|
370
|
|
Input Current
|
A
|
0.0273(AC110V) 0.014(AC220V)
|
|
Input surge current
|
A
|
20
|
|
2.2
Output characteristics
2.2.1
Output regulation characteristics
The output voltage
|
Minimum current
|
Maximum current
|
Peak current
|
The output voltage range
|
Ripple
|
+5V
|
0A
|
2000mA
|
2200mA
|
4.80~5.2V
|
60mV
|
2.2.2
Other output characteristics
Item
|
Unit
|
Min
|
Typ
|
Max
|
Test Conditions
|
Output Power
|
W
|
0
|
10
|
11
|
DC output power
|
Output efficiency
|
%
|
|
80
|
|
Rated load
|
Overshoot switch
|
%
|
|
|
10
|
|
Output rise time
|
mS
|
|
|
100
|
|
2.3
Protection
Item
|
Unit
|
Yes / No
|
Minimum
|
Typical
|
Maximum
|
Recovery Characteristics
|
Power output over
|
|
Have
|
|
|
|
Lock, after re-starting recovery
|
Rate Protection
|
|
Have
|
|
|
|
Automatic recovery after the fault
is removed
|
Short circuit protection
|
|
Have
|
|
|
|
Lock, after re-starting recovery
|
Temperature protection
|
|
Have
|
|
|
|
Lock, after re-starting recovery
|