SEAFLO non-automatic bilge pumps offer water evacuation activated by a panel or float switch. Our larger impeller design and more robust motor allow us to outperform our competitors. Our removable strainer base fits industry standard mounting conventions though, so you’ll have no problem changing to us from them.
- Run dry capable for normal workloads
- Quiet operation
- 110°F (43°C) temperature limits
- 2 Year Warranty
- Meets or exceeds ABYC, SAE, and ISO standards
- Traditional operation by switch or float switch
- Entirely submersible
DIMENSIONS
STANDARD PUMP CONFIGURATIONSModel | Flow Rate | Voltage | Max Draw | Fuse Amps | Head | Wire Lead | Outlet Dia | N.W. / G.W. | SFBP1-G750-01 | 675 GPH | 12 V | 5.0 A | 5.0 A | 8.2' (2.5 m) | 3' (1 m) | 3/4" | 0.33/0.40 kg | SFBP2-G750-01 | 703 GPH | 24 V | 4.0 A | 2.0 A | 8.5' (2.6 m) | 3' (1 m) | 3/4" | 0.33/0.40 kg |
PERFORMANCE Voltage(V) | Current(A) | Flow | Head(M) | GPH | LPH | OPEN | 2.5 | 675 | 2554 | 0 | 12 | 3.05 | 537 | 2032 | 0.5 | 12 | 3.64 | 377 | 1427 | 1 | 12 | 4.36 | 286 | 1082 | 1.5 | 12 | 4.62 | 145 | 459 | 2 | 12 | 5 | 0 | 0 | 2.5 |
| | Voltage(V) | Current(A) | Flow | Head(M) | GPH | LPH | OPEN | 1.27 | 703 | 2660 | 0 | 24 | 1.65 | 566 | 2142 | 0.5 | 24 | 2.42 | 384 | 1453 | 1 | 24 | 3.02 | 279 | 1056 | 1.5 | 24 | 3.52 | 154 | 583 | 2 | 24 | 4 | 0 | 0 | 2.6 |
|
PERFORMANCE
|